Development of detection geometry for Thin Layer Activation experiments

Autores

  • Michel de Almeida França Instituto de Engenharia Nuclear
  • César Marques Salgado Instituto de Engenharia Nuclear
  • Júlio Cezar Suita Instituto de Engenharia Nuclear

Palavras-chave:

Thin Layer Activation, geometry of detection, wear, MCNP-X

Resumo

In this work the parameters for a counting geometry of a Thin Layer Activation device were determined using MCNP-X code simulations and an experiment to verify the counting system's reliability.

Biografia do Autor

Michel de Almeida França, Instituto de Engenharia Nuclear

CENS

César Marques Salgado, Instituto de Engenharia Nuclear

DIRA

Júlio Cezar Suita, Instituto de Engenharia Nuclear

DIRA

Referências

INTERNATIONAL ATOMIC ANGENCY ENERGY. Thin layer activation (TLA) technique for wear measurement. Vienna: IAEA, 2017a. Disponível em: <https://www-nds.iaea.org/tla/>Acesso em: 28 mar. 2018.

FEHSENFELD, P.; KLEINRAHM, A.; SCHWEICKERT, H. Radionuclide technique in mechanical engineering in Germany. Journal of radioanalytical and nuclear chemistry, [S.l], v. 160, n. 1, p. 141-1511992.

INTERNATIONAL ATOMIC ANGENCY ENERGY. Calculation tool for thin layer Application, TLA2. Vienna: IAEA, 2017b. Disponível em: <https://www-nds.iaea.org/tla/.> Acesso em: 28 mar. 2018.

Downloads

Publicado

2021-07-08

Como Citar

França, M. de A., Salgado, C. M., & Suita, J. C. (2021). Development of detection geometry for Thin Layer Activation experiments. Instituto De Engenharia Nuclear: Progress Report, (3), 36. Recuperado de https://revistas.ien.gov.br/index.php/ienprogressreport/article/view/348

Edição

Seção

Application of Nuclear Techniques in Health and Environment