RADIATION MONITORING SYSTEM
Palavras-chave:
Nuclear instrumentation, Radiation Monitoring.Resumo
Design of a portable low-power multichannel analyzer with wireless connectivity for remote radiation monitoring, powered from a solar panel with a internal battery to be operated in field. The multichannel analyzer is based on a single microcontroller which performs the digital functions and an analog signal processing board for implementing a Gaussian shaper preamplifier, a Gaussian stretcher, sample and hold, pile-up rejector and a 10 bit ADC. Now this design is to be used with a NaI(Ti) scintillator detector.This multichannel analyzer is designed to be a part of radiation monitoring network. All of them are connected, by radio in a radius of 10 kilometers, to a supervisor computer that collects data from the network of multichannel analyzers and numerically display the latest radiation measurements or graphically display measurements over time for all multichannel analyzers. Like: dose rate, spectra and operational status. Software also supports remotely configuring operating parameters (such as radiation alarm level) for each monitor independently.
Referências
. M. V. Oliveira, M. A. C. Aghina, M. Soares, “Sistema de Monitoração de Radiação7027”, Proceedings of 4th Meeting on Nuclear Applications (IV ENAN), Poços de Caldas,Brazil, August 1997, Vol. 1, pp. 473-476 (1997).
Luiz Tauhata, Ivan P.A.Salati, Renato Di Prinzio, Antonieta R.Di Prinzio, "Radioproteção e Dosimetria: Fundamentos ", Instituto de Radioproteção e Dosimetria, ,5ªRevisão-Agosto/2003,www.cnen.gov.br/seguranca/documentos/FundamentosCORv5.pdf
. M. A. C. Aghina, M. S. Farias, F. Lacerda, A. Heimlich, “Radiation Monitoring System”, (INAC 2015), São Paulo, Brazil, October 2015.