Calculation of velocity for single-phase flow based on radioactive particle tracking
Palavras-chave:
radioactive particle tracking, velocity, gamma radiationResumo
This report demonstrates the calculation of velocity of fluids by using particle tracker injection. The required data was obtained by the MCNP-X code. The geometry setup consists of two NaI(Tl) detectors and 137Cs was used as particle tracker in the studies.Referências
HANUS, R. et al. Time delay estimation in two-phase flow investigation using the ?-ray attenuation technique, Mathematical Problems in Engeenering,[S.l], v. 2014, [s.n], p. 1-10, 2014.
BENDAT, J. S.; PIERSOL, A. G. Random data: analysis and measurement procedures. 4. ed. New York: John Wiley, 2010. 640p.
Downloads
Publicado
2021-07-08
Como Citar
Salgado, C. M., Dam, R. S. de F., & Candeiro, R. E. de M. (2021). Calculation of velocity for single-phase flow based on radioactive particle tracking. Instituto De Engenharia Nuclear: Progress Report, (3), 34. Recuperado de https://revistas.ien.gov.br/index.php/ienprogressreport/article/view/345
Edição
Seção
Application of Nuclear Techniques in Health and Environment
Licença
Copyright (c) 2018 César Marques Salgado, Roos Sophia de Freitas Dam, Ricardo Elias de Miranda Candeiro