Scanner device to monitor deposits inside pipelines using gamma scattering methodology

Autores

  • Eduardo Gomes dos Santos
  • Lui­s Eduardo Barreira Brandão Instituto de Engenharia Nuclear - Conselho de Pesquisa e Ensino

Resumo

A flow rate measurement system must be adequately designed for the specific measurement task and correctly estimate the measurements. In radiotracer flow measurements methodology is important to select the measure positions P1 and P2 where the scintillator detectors were installed. These positions must be far from any interference to guarantee an accurate result. A special device using a gamma source was constructed and used to locate solid deposits inside the duct because in this flow measurements is essential to check the pipeline condition because the volume V between the two measure positions must be full of the fluid.

Downloads

Publicado

2021-08-12

Como Citar

Gomes dos Santos, E., & Brandão, L. E. B. (2021). Scanner device to monitor deposits inside pipelines using gamma scattering methodology. Instituto De Engenharia Nuclear: Progress Report, (4). Recuperado de https://revistas.ien.gov.br/index.php/ienprogressreport/article/view/491

Edição

Seção

Application of Nuclear Techniques in Industry